missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Vivid™ CYP2J2 Cyan Screening Kit

Vivid™ CYP450 Screening Kits are high-throughput fluorescence-based assays for detection of enzyme-drug interactions and CYP450 inhibition.

Marke:  Thermo Scientific™ PV6142

Artikelnummer. 15594404

  • 610.00 CHF / 300 Stück
Verfügbar ab: 08-10-2024
Sie sich ein, um den Lagerbestand zu sehen
Entdecken Sie weitere Sonderangebote
Zum Warenkorb hinzufügen
Dieser Artikel kann nicht zurückgegeben werden. Rückgaberichtlinie anzeigen

Beschreibung

Beschreibung

Vivid™ CYP450 Screening Kits are high-throughput fluorescence-based assays for detection of enzyme-drug interactions and CYP450 inhibition. They provide an optimized method for studying isozyme-specific CYP450-drug interactions, metabolism, and inhibition.

Vivid™ CYP450 Screening Kits offer:

  • Easy three-step procedure, 'mix and read' format, reactions at room temperature or 37°C
  • Superior fluorescent properties and kinetics compared to conventional fluorogenic probes
  • High signal-to-background ratio, broad dynamic range
  • Compatible with multiple assay formats from 96-well to 1536-well

Simple Mix and Read Kit Format

Vivid™ CYP450 Screening Kits include Vivid™ Substrate, Vivid™ Fluorescent Standard, reaction buffer, Vivid™ Regeneration System, NADP+, and CYP450 BACULOSOMES™ Plus Reagents. The CYP450 BACULOSOMES™ Plus Reagents are microsomes prepared from insect cells expressing a human CYP450 isozyme (CYP2J2 in this case) and human cytochrome-P450 reductase. CYP450 BACULOSOMES™ Plus Reagents offer a distinct advantage over human liver microsomes in that only one CYP450 isozyme is expressed, thereby preventing metabolism by other CYP450s.

Unique Vivid™ Reagents for Bright Fluorescent Signals and Low Background

Vivid™ Substrates are blocked dyes that yield minimal fluorescence signal until cleaved or hydroxylated. Oxidation at either of two potential sites releases the highly fluorescent product (Figure 1). They have superior fluorescence, solubility, and kinetic properties compared to conventional fluorogenic probes. This results in higher sensitivity, greater signal-to-noise ratio, and better assay reproducibility. Vivid™ MOBFC Substrate is the substrate included in this particular kit. This substrate yields a product that emits a cyan fluorescence.

Flexible Assay Formats for Optimized Results

The sensitivity of the Vivid™ CYP450 assays allows detection of weak inhibitors and miniaturization to as little as 2 μl per reaction. Assays may be set up in kinetic mode or in end-point mode to facilitate multi-plate screening (Figure 2). Assays may be performed at room temperature or 37°C.

Applications:

  • High-throughput screening of enzyme-drug interactions
  • Compound profiling for drug inhibition of cytochrome P450 isozymes
  • Generation of predictive SAR models to guide compound acquisition
TRUSTED_SUSTAINABILITY
Spezifikation

Spezifikation

Leuchtstoffarmer™ CYP J Cyan-Screening22-Kit,300 Assays, Cyan-Farbe, Fluoreszenzdetektionsmethode, Cytochrom P450-Druggiebelziel, CYP2 J2-Nachweisziel, menschliche Spezies, verwendet in Zellviabilität, Proliferation und Funktion, Pharma und Biopharma, Protein-Assays
VIVID™
Zellviabilität, -proliferation und -funktion, Pharma und Biopharma, Protein-Assays und -Analyse, zielbasierte ADME/tox-Assays, Proteinbiologie, Zellanalyse, Zellstoffwechsel, Arzneimittelforschung und -entwicklung, biochemische ADME-Assays, Cytochrom-p450-Hemmung-ADME-Assays, Protein-Assays und -Analyse, Cytochrom-p450-Aktivität
1 Röhrchen Reaktionspuffer, bei Raumtemperatur lagern
1 Röhrchen BACULOSOMES™ Plus Reagenz, bei -80 °C lagern
1 Röhrchen Vivid™ Regenerationssystem, bei -80 °C lagern
1 Röhrchen Vivid™ NADP +, bei -80 °C lagern
1 Röhrchen Vivid™ Substrat und 1 Röhrchen Vivid™ Fluoreszenzstandard, bei -20 °C lagern, vor Licht schützen
Screening-Kit
Cyan
Human
Mikrotiterplatten-Lesegerät
Cytochrom P450
1 Röhrchen Reaktionspuffer,1 Röhrchen BACULOSOMES™ plus Reagenz, 1 Röhrchen Vivid™ Regenerationssystem, 1 Röhrchen Vivid™ NADP+, 1 Röhrchen Vivid™ Substrat und 1 Röhrchen Vivid™ Fluoreszenz-Standard
Fluoreszent
300 Assays
Trockeneis
Produktvorschläge

Produktvorschläge

Videos
Sicherheitsdatenblatt (SDS)
Dokumentation

Dokumentation

Zertifikate
Sonderangebote

Sonderangebote

For Research Use Only. Not for use in diagnostic procedures.